Pump is not working |
No voltage or power is off. |
Re-starts the power |
Cable wire is fractured |
Replaces it |
Fuse or circuit burns up |
Replaces it |
Power source has poor contact |
Re-connects it again. |
It has a little noise, but not working. |
Switch has poor contact that cause open phase |
Adjusts connection parts. |
Cable wire is fractured that cause open phase |
Replaces it |
Motor wiring is fractured that cause open phase |
Replaces it |
Bearing is defective |
Replaces it |
Motor shaft is not balanced |
Replaces it |
Single phase capacitor is defective |
Replaces it |
Generator capacity is not enough |
Replaces it to larger capacity |
Voltage drops |
Adjusts power & voltage |
Something stuck inside the pump |
Dismantles the pump and cleans it. |
When pump starts, it will stop immediately. |
Voltage drops |
Adjusts power & voltage |
Generator capacity is not enough |
Replaces it to larger capacity |
3 phase voltage is unstable |
Adjusts power; replaces impeller |
Liquid contains mud or sand |
Negotiates with customer |
Liquid viscosity is too high |
Negotiates with customer |
Liquid temperature is too high |
Negotiates with customer |
Reverse phase in 3 phase |
Replaces 2 wires in 3 phase wires. |
The capacity is not enough or the head is low |
Impeller is stuck or damaged |
Cleans or replaces it |
Motor reverse phase |
Replaces 2 wires in 3 phase wires. |
Pipeline or valve is leaking or stuck |
Checks where the leakage is in pipeline or valve |
Actual performance can’t reach customer requirements |
Replaces it to better pump model |